Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
J. appl. oral sci ; 31: e20230104, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1448550

ABSTRACT

Abstract The formation of biofilm on denture bases is a recurrent clinical problem that favors the development of denture stomatitis. The effectiveness of a hygiene protocol in a 3D-printed denture base resin is still uncertain. Objective To evaluate of the effectiveness of immersion, associated or not with brushing in a soap solution, on the biofilm control of a 3D-printed denture base resin. Methodology Specimens of denture base resins [Cosmos Denture (COS) and Classico (CLA/control)] were contaminated in vitro with Candida albicans and immersed in sodium hypochlorite 0.25% (SH, alkaline peroxide) AP, chlorhexidine digluconate 2% (CD or PBS-Control), associated or not with brushing with 0.78% Lifebuoy soap. Roughness was evaluated before and after brushing and immersion. The effectiveness of the protocols was assessed by CFU/mL, cellular metabolism (XTT), scanning electron microscopy (SEM), and confocal scanning laser microscopy. Data were analyzed by T student, ANOVA/Welch, and Tukey/Gomes-Howell pos-hoc tests (α = 0.05). Results CLA showed greater roughness than COS. CFU/mL and XTT were higher in COS resin with a higher hyphae formation. Immersion in SH and CD eliminated CFU/mL and reduced XTT for both resins, associated or not with brushing. AP reduced CFU/mL only when associated with brushing. Conclusions The biofilm on the 3D-printed resin was thicker and presumably more pathogenic, regardless of its smoother surface. Immersions in SH 0.25% and CD 2% are effective hygiene protocols for both resins, associated or not with brushing. AP should be recommended when associated with brushing with a Lifebuoy 0.78% solution.

2.
J. appl. oral sci ; 28: e20200092, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1134775

ABSTRACT

Abstract The period of functional adaptation to a new conventional complete denture embraces many transitory issues, and this period is directly related to the rehabilitation success. Objective This clinical trial evaluated the influence of the height of mandibular ridge on the masticatory function of complete denture (CD) wearers during the adaptation period. Methodology A total of 28 individuals wearing new CDs (NR, n=14, normal mandibular ridges, 64±12.5 years, 9 female; RR, n=14, resorbed mandibular ridges, 69±6.8 years, 9 female) were assessed at 24 hours, 30 days, three months and six months after the insertion of the CDs for masticatory performance (MP, sieves method), satisfaction with CDs (questionnaire) and maximum occlusal bite force (MOBF) (gnatodynamometer). The classification of the mandibular ridges followed the Kapur index. Data of MP and MOBF were analyzed by two-way ANOVA and satisfaction with CDs was analyzed by Generalized Estimating Equations (GEE), α=.05. Results Participants with NR presented better masticatory performance (p=.000 - NR 30.25±9.93%, RR 12.41±7.17%), general satisfaction (p=.047), retention of mandibular denture (p=.001), chewing ability (p=.037), and comfort of wearing a mandibular denture (p=.000). Regardless of the mandibular ridge, MP (p=.000) was higher at three (21.26±12.07%) and six months (24.25±12.26%) in comparison to 24 hours (18.09±10.89%), the MOBF (p=.000) was higher at three months (78.50±6.49 N) compared to 24 hours (57.34±5.55 N) and 30 days (62.72±5.97 N), and the comfort of wearing a mandibular denture (p=.002) at three months (1.61 ± 0.07) was greater than 24 hours (1.29±0.10) and 30 days (1.36±10). Conclusions The study suggests that the participants with NR have higher MP and satisfaction with their CD, regardless of the follow-up period after the insertion of the new CD. After subjects received the CD, a period of 3 months was necessary for achieving better achievement MOBF, MP, and self-perceived comfort with the mandibular denture, regardless of the height of the mandibular ridge.


Subject(s)
Humans , Male , Female , Aged , Denture, Complete , Mandible/anatomy & histology , Mastication , Bite Force , Surveys and Questionnaires , Patient Satisfaction , Dental Occlusion , Middle Aged
3.
Braz. dent. j ; 29(6): 576-582, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-974198

ABSTRACT

Abstract Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values ​​were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.


Resumo Vários sistemas de encaixe para sobredentaduras mandibulares implantossuportadas estão atualmente disponíveis e estudos são necessários para entender as suas propriedades mecânicas. O objetivo deste estudo foi avaliar a força de retenção e as características de desgaste de três sistemas de encaixe por meio de uma simulação de deslocamento cíclico de sobredentaduras implantossuportadas. Trinta amostras foram fabricadas e divididas em 3 grupos: 1-O-ring; 2-Mini Ball; e 3-Equador. Um teste de fadiga mecânica foi aplicado aos espécimes utilizando uma máquina de teste universal servo-hidráulica com 5500 ciclos de inserção/remoção (f = 0,8 Hz), imersos em saliva artificial. Os valores da força de retenção foram obtidos antes e após 1500, 3000 e 5500 ciclos utilizando uma velocidade de 1 mm/min e uma célula de carga de 1 kN. Um espécime de cada grupo foi selecionado aleatoriamente e analisado por microscopia eletrônica de varredura. O teste de Análise de Variância a dois fatores para medidas repetidas e o teste de comparações múltiplas de Bonferroni foram utilizados para análises estatísticas (α = 0,05). O sistema de O-ring permaneceu estável durante todos os períodos testados e apresentou valores de força de retenção significativamente menores do que os sistemas Mini Ball e Equator. O sistema Mini Ball apresentou um aumento significativo na força de retenção após o teste mecânico (controle = 21,04 ± 3,29N; 5500 ciclos = 24,01 ± 3,30N). O sistema Equator apresentou uma diminuição significativa na força de retenção após cada período testado, mas os valores eram maiores do que os outros sistemas. O tipo de sistema de encaixe influenciou na força de retenção de diferentes maneiras após testes mecânicos. O sistema do Equador exibiu os maiores valores de força de retenção. As matrizes dos sistemas Mini Ball e Equator produziram deformação e desgaste nas superfícies sem ruptura dos anéis de poliamida.


Subject(s)
Humans , Dental Prosthesis, Implant-Supported , Denture, Overlay , Denture Precision Attachment , Saliva, Artificial , Tensile Strength , Materials Testing , Dental Stress Analysis
4.
Rev. odontol. UNESP (Online) ; 47(3): 143-148, maio-jun. 2018. tab, ilus
Article in English | LILACS, BBO | ID: biblio-961516

ABSTRACT

Introduction: Temporomandibular disorders (TMD) can compromise masticatory performance due to the presence of pain, muscular dysfunction and limitation of mandibular movements. Substantial improvements in TMD pain can be achieved through therapeutic approaches including education and self-care. Objective: The aim of the present study was to investigate the impact of these treatment modalities in the masticatory performance of women with painful TMD. Material and method: Fifty-two women were randomly divided into three groups: Control Group (CG); Education Group (received education about TMD) (EG); Self-Care and Education Group (received education about TMD and instructions self-care therapies) (SEG). The education instructions about TMD and self-care therapies were transmitted through a video and printed illustrative material. The masticatory performance was evaluated through the sieves method ​​with natural tested foods in the evaluation periods: baseline evaluation, 30 days after and 60 days of follow-up. Data were analyzed and used with a one-way ANOVA parametric test for mean comparison of CG, EG and SEG groups (α = 0.05). Result: The masticatory performance of the participants was similar, irrespective of the proposed treatments, at baseline (p=.604), 30 days (p=.450) and 60 days (p=.669). Conclusions: The results indicated that treatment with educational and self-care therapies over a period of 60 days had no impact on the masticatory performance of women with painful TMD.


Introdução: As disfunções temporomandibulares (DTM) podem comprometer a capacidade mastigatória devido à presença de dor, disfunção muscular e limitação dos movimentos mandibulares. Melhorias substanciais da dor relacionada à DTM podem ser alcançadas através de abordagens terapêuticas incluindo a educação e os autocuidados. Objetivo: O objetivo do presente estudo foi investigar o impacto dessas modalidades de tratamento no desempenho mastigatório de mulheres com DTM dolorosa. Material e método: Cinquenta e duas mulheres foram divididas aleatoriamente em três grupos: Grupo Controle (CG); Grupo Educação (receberam instruções sobre DTM) (EG); Grupo de Autocuidado e Educação (receberam instruções sobre DTM e instruções sobre terapias de autocuidado) (SEG). As instruções de educação sobre DTM e terapias de autocuidado foram transmitidas através de vídeo e material ilustrativo impresso. O desempenho mastigatório foi avaliado através do método dos tamises com alimentos testes naturais nos períodos de avaliação: atendimento inicial, 30 dias após e ao fim de 60 dias de acompanhamento. Os dados obtidos, em porcentagem, foram analisados e foi utilizado o teste paramétrico ANOVA one-way para comparação das médias dos grupos CG, EG e SEG (α= 0,05). Resultado: O desempenho mastigatório dos participantes foi semelhante, independentemente dos tratamentos, no atendimento inicial (p=0,604), após 30 dias (p=0,450) e após 60 dias (p=0,669). Conclusão: Os resultados indicam que o tratamento com terapias educativas e de autocuidado durante um período de 60 dias não teve impacto no desempenho mastigatório das mulheres com DTM dolorosa.


Subject(s)
Humans , Female , Self Care , Women , Temporomandibular Joint Disorders , Temporomandibular Joint Dysfunction Syndrome , Analysis of Variance , Mastication
5.
Rev. odontol. UNESP (Online) ; 45(4): 195-200, July-Aug. 2016. tab, ilus
Article in English | LILACS, BBO | ID: lil-795233

ABSTRACT

Introduction: The staining of artificial teeth can be related to the acrylic resin abrasion caused by brushing, resulting in higher deposition of dyes from the beverage, and consequently higher aesthetic damage. Objective: The aim of this in vitro study was to evaluate methods for removal of stains from acrylic denture teeth using spectrophotometric analysis. Material and method: Artificial teeth were divided into twelve groups (n=10) according to the type of treatment (re-polishing - Re or immersion in Corega Tabs - Sp), staining solutions, coffee (Cf) and Coca-Cola® (Cc) or water (W) and with/without toothbrushing (B). The Sp specimens were submitted to seven immersion cycles (5 min each). The Re specimens were polished with pumice stone followed by Spain white paste. Color differences (ΔE) were captured by a spectrophotometer: T0 (baseline), T1 (after brushing/immersion in solutions) and T2 (after Re or Sp). Result: Statistically significant color change between T1 and T2 (paired T-test; α =.05) was observed for the group CfSp (p=.032); and for the groups BWRe (p=.000), BCfRe (p=.049) and CcRe (p=.042). Higher color changes were observed for the specimens submitted to toothbrushing (ANOVA two way; p<.001). Conclusion: It could be concluded that the immersion in sodium perborate (Corega Tabs) can be used for removal of coffee stains from denture teeth, and re-polishing for removal of Coca-Cola® stains. Still, toothbrushing produced greater color changes on denture teeth, regardless of the immersion solution.


Introdução: O manchamento dos dentes artificiais pode estar relacionado à abrasão da resina acrílica provocada pela escovação, resultando na maior deposição de corantes provenientes de bebidas, e consequentemente maior prejuízo estético. Objetivo: O objetivo do presente estudo foi avaliar métodos de remoção de manchas extrínsecas por meio de analise com espectofotômetro. Material e método: Dentes artificiais foram divididos em 12 grupos (n=10), de acordo com o tipo de tratamento (repolimento – Re ou imersão em perborato de sódio, Corega Tabs – Sp), tipo de solução de manchamento, café (Cf) ou Coca-Cola® (Cc) ou água (W) e com/sem escovação (B). Os métodos de remoção de manchas propostos (Re e Sp) foram realizados de acordo com protocolos pré-estabelecidos. Os espécimes Sp foram submetidos a 7 ciclos de imersão (5 minutos cada). O repolimento foi realizado com pastas de pedra pomes e branco de espanha, utilizando escovas de cerdas macias e rodas de feltro. As leituras de estabilidade de cor (ΔE) foram realizadas por meio de um espectrofotômetro: T0 (baseline), T1 (após escovação/imersão em bebidas), e T2 (após Re ou Sp). Resultado: Alterações de cor entre T1 e T2 (teste T pareado; α=0,05) foram observadas para o grupo CfSp (p=.032); e para os grupos BWRe (p=.000), BCfRe (p=.049) e CcRe (p=.042). Os dentes artificiais submetidos à escovação mostraram maior alteração de cor (ANOVA 2 fatores; p<0,001). Conclusão: Conclui-se que a imersão em perborato de sódio (Corega Tabs) pode ser utilizada para remoção de manchas de café e o repolimento para remoção de manchas de Coca-Cola®. Ainda, a escovação produziu as maiores alterações de cor nos dentes artificiais, independentemente da solução de imersão.


Subject(s)
Tooth, Artificial , Toothbrushing , Acrylic Resins , In Vitro Techniques , Color , Denture, Complete , Esthetics, Dental , Tooth Abrasion , Beverages , Spectrophotometers , Coffee , Coloring Agents
6.
Braz. dent. j ; 25(5): 391-398, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-731052

ABSTRACT

The aim of the present study was to assess the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Fifty edentulous patients received a set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment protocols: Protocol 1- DA use during the first 15 days, followed by no DA for the next 15 days; Protocol 2- no DA during the first 15 days, followed by use of DA for the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to assess the patients´ satisfaction. A kinesiograph was used to record mandible movements and patterns of maxillary complete denture movement during chewing. The Wilcoxon test (α=0.05) and a paired sample t-test (α=0.05) were used to compare satisfaction levels and kinesiographic data, respectively. Use of DA improved the overall level of patient satisfaction (p<0.001). The kinesiographic recordings revealed a significant increase (1.7 mm) in vertical mandible movements (p<0.001) during chewing and a lower (0.3 mm) vertical intrusion of the maxillary complete dentures (p=0.002) during chewing after using the DA. Use of DA in complete denture wearers improved the patients´ satisfaction and altered mandible movements, with increases in vertical movements during chewing and less intrusion of maxillary complete dentures.


O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo "cross-over". Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: Protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; Protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo nos próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de "Wilcoxon" (α=0,05) e o "t-test" de Student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7 mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3 mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação.


Subject(s)
Animals , Male , Rats , Gastrin-Secreting Cells/metabolism , Gastrins/metabolism , Somatostatin-Secreting Cells/metabolism , Somatostatin/metabolism , Stomach Ulcer/physiopathology , Disease Models, Animal , Gastric Mucosa/cytology , Gastric Mucosa/metabolism , Rats, Wistar , Stomach Ulcer/chemically induced
7.
Rev. Assoc. Paul. Cir. Dent ; 68(1): 75-78, jan.-mar. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-715024

ABSTRACT

A Síndrome da Combinação representa uma importante condição patológica do sistema mastigatório que precisa de um tratamento reabilitador complexo. A presença de mucosa flácida é uma das caraterísticas mais comuns quando ocorre a reabsorção óssea anterior da pre-maxila ocasionada pela hiperfunção anterior dos dentes inferiores sobre a prótese total superior, onde a incidência de cargas nessa região resulta na movimentação da pró tese em direção ao rebordo, resultando no aumento da reabsorção do rebordo residual, na desadaptação interna da prótese e na perda de retenção da prótese. A presença de mucosa flácida, nesses casos, acarreta ainda problemas de suporte e estabilidade da prótese total superior, que podem ser tratados com redução cirúrgica da espessura do tecido ou usando técnicas específicas de confecção das próteses. Este artigo descreve a reabilitação oral de um paciente com Síndrome da Combinação onde a redução cirúrgica da mucosa flácida não foi realizada, utilizando uma técnica modificada de moldagem funcional em duas etapas, com o objetivo de gerar menos forças e distorções na fibromucosa flácida durante a moldagem funcional.


The Combination Syndrome represents an important pathologic condition of the masticatory system that requires a complex rehabilitation treatment. The presence of flaccid mucosa is one of the most common features due to bone resorption of the pre-maxilla caused by anterior hyperfunction of the mandibular teeth on the maxillary complete denture, where the impact of oclusal loading in this region results in movement of the maxillary prosthesis into the ridge, resulting in increased resorption of the residual ridge, internal misfit and 1055 of the retention of the maxillary complete denture. The presence of flaccid mucosa, in such cases, leads to problems of support and stability of the maxillary complete denture, which can be treated by surgical reduction of the thickness of the tissue or using specific techniques of fabrication of prostheses. This article describes the oral rehabilitation of a patient with the Combination Syndrome where the surgical reduction of flaccid mucosa was not performed, using a modified technique of functional impression in two steps, with the objective of generating forces and less distortion in flaccid mucosa during functional impression.


Subject(s)
Humans , Female , Aged , Dental Impression Technique , Dental Occlusion , Mouth Rehabilitation
8.
ImplantNews ; 11(3): 363-367, 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-730881

ABSTRACT

A utilização de diferentes métodos e materiais deve ser considerada durante o planejamento de próteses implantossuportadas. Complicações, como fraturas da base de resina acrílica, desgaste e fratura dos dentes, podem ocorrer com frequência, gerando a necessidade de um planejamento cuidadoso para cada paciente, o que pode tornar a seleção do tipo de tratamento mais complexa. Diante disso, este artigo descreve a reabilitação oral de um paciente totalmente edêntulo, portador de prótese tipo protocolo bimaxilar, que apresentava queixa estética, perda de dimensão vertical e fratura em dentes de resina acrílica do arco superior. Após o restabelecimento da dimensão vertical, realizou-se a substituição de suas próteses antigas por uma nova prótese tipo protocolo bimaxilar, sendo que a cerâmica foi utilizada como material de cobertura para o arco superior, e resina como material de cobertura para o arco inferior. Ao final do tratamento, o paciente recebeu placas oclusais lisas bimaxilares para proteger os dentes e implantes de possíveis hábitos parafuncionais. A forma como o tratamento foi conduzido permitiu uma resolução rápida e eficaz, com resultado estético e funcional muito favorável para o paciente.


The use of different methods and materials should be considered during the planning of implant-supported prostheses. Complications such as fractures of the acrylic resin base, wear and fracture of teeth can occur frequently, creating the need for careful planning for each patient, which can make the selection of the type of treatment more complex. Thus, this article describes the oral rehabilitation of a completely edentulous patient with bimaxillary fixed implant-supported prosthesis, with complaints on aesthetics, loss of vertical dimension and fracture of acrylic resin teeth of the upper arch. After the restoration of vertical dimension, his dentures were replaced with new bimaxillary implant-supported fixed prostheses, ceramic and acrylic resin were used as veneering material for maxilla and mandible, respectively. At the end of the treatment, the patient received bimaxillary flat occlusal splints to protect the teeth and implants of possible parafunctional habits. The approach for the treatment allowed a quick and effective resolution, with aesthetic and functional outcomes very favorable for the patient.


Subject(s)
Humans , Male , Middle Aged , Acrylic Resins , Jaw, Edentulous , Prostheses and Implants
9.
Rev. odontol. UNESP (Online) ; 42(4): 237-242, jul.-ago. 2013. ilus, tab
Article in English | LILACS, BBO | ID: lil-685536

ABSTRACT

Introduction: The occurrence of stomatitis is common since the surface characteristics of the dentures may act as reservoirs for microorganisms and have the potential to support biofilm formation. Purpose: To assess the surface properties (wettability/roughness) and color stability of an acrylic resin combined with the antimicrobial polymer poly (2-tert-butylaminoethyl) methacrylate (PTBAEMA). Material and Method: Thirty disc-shaped specimens of an acrylic resin (Lucitone 550) were divided into three groups: 0% (control); 5% and 10% PTBAEMA. Surface roughness values (Ra) were measured using a profilometer and wettability was determined through contact angle measurements using a goniometer and deionized water as a test liquid. Color data were measured with a spectrophotometer. Kruskal-Wallis and Dunn's test were used to compare roughness values. Wettability data were analyzed using ANOVA and Tukey's test. Color data were compared using the Student's t-test and ∆E values were classified according to the National Bureau of Standards (NBS). All statistical analyses were performed considering α=.05. Result: Significant differences (p<.05) were detected among the groups for roughness, wettability and color stability. According to the NBS, the color changes obtained in the 5% and 10% PTBAEMA groups were "appreciable" and "much appreciable", respectively. Conclusion: It could be concluded that PTBAEMA incorporation in an acrylic resin increased the roughness and wettability of surfaces and produced color changes with clinical relevance.


Introdução: A ocorrência de estomatite protética é relativamente comum uma vez que as superfícies das próteses bucais representam um ambiente propício para adesão de microrganismos orais e formação de biofilme. Objetivo: Avaliar as propriedades de superfície (molhabilidade/rugosidade) e estabilidade de cor de uma resina acrílica combinada com o polímero antimicrobiano poli (2-tert-butilaminoetil) metacrilato (PTBAEMA). Material e Método: Trinta espécimes em formato de disco de uma resina acrílica (Lucitone 550) foram divididos em três grupos: 0% (controle), 5% e 10% PTBAEMA. Os valores de rugosidade (Ra) foram medidos utilizando um rugosímetro, e a molhabilidade foi determinada através de medições de ângulo de contato utilizando um goniômetro e água deionizada como líquido teste. Dados de cores foram medidos com um espectrofotômetro. Os testes de Kruskal-Wallis e Dunn foram utilizados para comparar os valores de rugosidade. Os dados de molhabilidade foram analisados utilizando-se ANOVA e teste de Tukey. Os dados de cor foram comparados com o teste t de Student e valores ΔE foram classificados de acordo com o National Bureau of Standards (NBS). Todas as análises estatísticas foram realizadas considerando α= 0,05. Resultado: Diferenças significativas (p<0,05) foram detectadas entre os grupos para rugosidade, molhabilidade, e estabilidade de cor. De acordo com o NBS, as alterações de cor obtidas nos grupos 5% e 10% PTBAEMA foram "marcante" e "extremamente marcante", respectivamente. Conclusão: Pode-se concluir que a incorporação de PTBAEMA em uma resina acrílica aumentou a rugosidade e molhabilidade das superfícies e produziu alterações de cor com relevância clínica.


Subject(s)
Acrylic Resins , Analysis of Variance , Wettability , Color , Statistics, Nonparametric , Products with Antimicrobial Action , Stomatitis, Denture , Spectrophotometers , Dental Plaque
10.
J. appl. oral sci ; 20(6): 643-648, Nov.-Dec. 2012. ilus, tab
Article in English | LILACS | ID: lil-660635

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the antimicrobial activity of an acrylic resin combined with an antimicrobial polymer poly (2-tert-butylaminoethyl) methacrylate (PTBAEMA) to inhibit Staphylococcus aureus, Streptococcus mutans and Candida albicans biofilm formation. MATERIAL AND METHODS: Discs of a heat-polymerized acrylic resin were produced and divided according to PTBAEMA concentration: 0 (control), 10 and 25%. The specimens were inoculated (10(7) CFU/mL) and incubated at 37ºC for 48 h. After incubation, the wells were washed and each specimen was sonicated for 20 min. Replicate aliquots of resultant suspensions were plated at dilutions at 37ºC for 48 h. The number of colony-forming units (CFU) was counted and expressed as log (CFU+1)/mL and analyzed statistically with α=.05. RESULTS: The results showed that 25% PTBAEMA completely inhibited S. aureus and S. mutans biofilm formation. A significant reduction of log (CFU+1)/mL in count of S. aureus (control: 7.9±0.8A; 10%: 3.8±3.3B) and S. mutans (control: 7.5±0.7A; 10%: 5.1±2.7B) was observed for the group containing 10% PTBAEMA (Mann-Whitney, p<0.05). For C. albicans, differences were not significant among the groups (control: 6.6±0.2A; 10%: 6.6±0.4A; 25%: 6.4±0.1A), (Kruskal-Wallis, p>0.05, P=0.079). CONCLUSIONS: Acrylic resin combined with 10 and 25% of PTBAEMA showed significant antimicrobial activity against S. aureus and S. mutans biofilm, but it was inactive against the C. albicans biofilm.


Subject(s)
Acrylic Resins/pharmacology , Biofilms/drug effects , Candida albicans/growth & development , Methacrylates/pharmacology , Staphylococcus aureus/growth & development , Streptococcus mutans/growth & development , Acrylic Resins/chemistry , Anti-Infective Agents/chemistry , Anti-Infective Agents/pharmacology , Biofilms/growth & development , Colony Count, Microbial , Denture Bases/microbiology , Methacrylates/chemistry , Stem Cells
11.
Rev. odontol. UNESP (Online) ; 41(1): 38-42, jan.-fev. 2012. tab, ilus
Article in English | LILACS, BBO | ID: lil-667003

ABSTRACT

Introdução: Estudos subjetivos sobre o conhecimento e uso de adesivos para prótese ainda são limitados, especialmente em populações brasileiras. Objetivo: O objetivo deste estudo foi investigar os aspectos relacionados ao uso ou não de adesivos para prótese por usuários de próteses totais. Material e método: Foram aplicados a 100 usuários de próteses totais bimaxilares questionários relativos à utilização de adesivos para prótese. A pesquisa foi realizada de acordo com três categorias: aqueles que nunca tinham utilizado o adesivo, aqueles que já tinham utilizado o adesivo pelo menos uma vez e que já não utilizavam mais, e aqueles que utilizam regularmente. Resultado: Dos 100 participantes, 80% nunca haviam utilizados adesivos, 16 porcentagem já haviam experimentado pelo menos uma vez, mas já não utilizavam mais e 4 porcentagem utilizavam regularmente. Conclusão: Dentro das limitações deste estudo, os resultados desta avaliação subjetiva sugerem que entre os participantes que nunca haviam experimentado adesivos, 77,5 porcentagem informaram que o adesivo não era necessário, e todos os participantes que utilizam regularmente informaram a sua eficiência.


Introduction: The information about the knowledge and usage of denture adhesives is still limited, particularly in Brazilian populations. Objective: The purpose of this study was to investigate the aspects related to the use or nonuse of denture adhesives by complete denture wearers. Material and method: Questionnaires were applied to 100 bimaxillary complete denture wearers concerning their usage of denture adhesives. The survey was carried out according to three categories: those who had never tried adhesive, those who had tried adhesive at least once but no longer used it, and those who currently used it. Result: Of the 100 participants, 80 percentage had never tried adhesives, 16 percentage had tried at least once but no longer used it and 4 percentage had used on a regular basis. Conclusion: Within the limitations of this study, the results of this subjective assessment suggest that within the participants that had never tried adhesives, 77.5 percentage inform that the adhesive is not needed, and all participants who regularly use it inform its efficiency.


Subject(s)
Humans , Male , Female , Adhesives , Surveys and Questionnaires , Denture, Complete , Brazil
12.
ImplantNews ; 9(5): 647-652, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-730026

ABSTRACT

Objetivos: o objetivo deste estudo foi avaliar o impacto da substituição de próteses totais convencionais mandibulares por próteses totais implantossuportadas sobre a qualidade de vida e os parâmetros cinesiográficos em pacientes desdentados totais bimaxilares. Métodos: indivíduos desdentados totais bimaxilares (n = 16) receberam próteses totais novas e após um período de adaptação (30 dias), a versão brasileira do Oral Health Impact Profile para indivíduos desdentados (Ohip-Edent) foi usada para avaliar a qualidade de vida relacionada à saúde oral dos participantes. Além disso, o cinesiógrafo K6-I (Myotronics Research Inc., Seattle, WA) foi utilizado pra realizar os registros dos movimentos máximos de abertura e fechamento e movimentação da prótese total superior durante a mastigação. Posteriormente, os indivíduos tiveram suas próteses totais convencionais mandibulares substituídas por próteses totais implantossuportadas e o mesmo protocolo de avaliação foi realizado após três e seis meses. Os resultados do Ohip foram avaliados utilizando os testes de Wilcoxon (α = 0,05) e os dados cinesiográficos avaliados por meio do teste t Student (α = 0,05). Resultados: os participantes apresentaram uma melhora significativa na qualidade de vida relacionada à saúde oral após três e seis meses de tratamento com próteses totais implantossuportadas. Os registros cinesiográficos demonstraram aumento significativo no movimento de abertura máxima vertical e nenhuma diferença significante foi encontrada no movimento da prótese total superior durante a mastigação após o tratamento com próteses totais implantossuportadas. Conclusão: a instalação de próteses totais implantossuportadas melhora a qualidade de vida dos pacientes e promove aumento na amplitude da abertura mandibular vertical.


Objectives: the objective of this study was to evaluate the impact of replacing conventional mandibular complete dentures by complete fixed dentures on the oral health-related quality of life and kinesiographic parameters of maxillary edentulous patients. Material and Methods: edentulous patients (n = 16) received one set of new complete dentures and after the intraoral adjustments and adaptation period (30 days), the Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (Ohip-Edent) was used to evaluate the oral health-related quality of life (OHQOL) of the participants. Additionally, the kinesiograph instrument K6-I (Myotronics Research Inc., Seattle, WA) was used to record opening and closure range of movement, mandibular movement, and the pattern of maxillary complete denture movement on chewing. Afterwards, the patients had their mandibular complete dentures replaced by a complete fixed denture and the same evaluation protocol was performed after 3 and 6 months. Ohip-Edent responses were analyzed using Wilcoxon’s test for repeated measures (α = .05) and Kinesiographic data using the Student´s t test (α = .05). Results: The Ohip-Edent showed an improvement of general oral health-related quality of life after 3 and 6 months of the treatment with complete fixed dentures. Kinesiographic recordings revealed a significant increase on maximum mandibular movements of vertical opening and no differences for the movement of the maxillary complete denture on chewing after treatment with complete fixed dentures was observed. Conclusion: the installation of complete fixed dentures improved the OHQOL and changed mandibular movements, with increases in vertical amplitude of maximal opening.


Subject(s)
Humans , Dental Implantation , Denture, Complete , Mandible , Mouth, Edentulous
13.
Rev. odontol. UNESP (Online) ; 40(5): 228-235, set.-out. 2011. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-614414

ABSTRACT

Introdução: Resinas acrílicas com atividade antimicrobiana poderiam oferecer aos pacientes usuários de próteses parciais e totais melhorias na sua saúde oral por meio de um melhor controle de biofilme. Objetivo: O objetivo deste estudo foi caracterizar quimicamente uma resina acrílica para base protética (Onda-Cryl), à qual foi incorporado o polímero antimicrobiano 2-tert-butilaminoetil (PTBAEMA), além de avaliar a resistência à flexão dessa resina. Material e método: Foram confeccionados espécimes de formato retangular a partir da resina acrílica contendo diferentes concentrações de PTBAEMA (0,5 e 10%). A superfície dos espécimes foi avaliada por meio de ESCA para detectar a presença de grupos amina, representada por índices de nitrogênio. As análises de FTIR e DSC foram utilizadas para avaliar o processo de polimerização e a influência da incorporação de PTBAEMA na Tgda resina, respectivamente. A resistência à flexão dos espécimes foi avaliada e os resultados foram analisados por meio de análise de variância a um fator (ANOVA), seguida pelo teste HSD de Tukey (α = 0,05). Resultado: Foram observados diferentes índices de nitrogênio para os grupos 0, 5 e 10% (0, 0,85 e 5,82%, respectivamente); houve copolimerização entre a resina e o PTBAEMA, e redução da Tg após incorporação. Foram encontradas diferenças significantes para a resistência à flexão (p < 0,05) cujos resultados foram 94,7 ± 9,4A, 21,8 ± 3,4B, 13,0 ± 1,5C MPa para os grupos 0,5 e 10%, respectivamente. Conclusão: A incorporação de PTBAEMA resultou em copolimerização,presença de grupos amina na superfície dos espécimes e diminuição da Tg e da resistência à flexão.


Introduction: Acrylic resins with antimicrobial activity could offer patients complete denture and partial wearers? improvement in their oral health by means of a better control of biofilm formation. Objective: The objective of this study was chemically characterize a denture base acrylic resin (Onda-Cryl) that was incorporated the antimicrobial polymer 2-tert-butylaminoethyl (PTBAEMA) and to evaluate the flexural strength of this resin. Material and method: Rectangular specimens were from a denture base acrylic resin with different concentrations of PTBAEMA(0,5 and 10%). Specimens' surfaces were assessed by ESCA to detect the presence of amine groups, represented by nitrogen ratios. Analysis of FTIR and DSC were used to evaluate the polymerization process and the influence of the incorporation of PTBAEMA in Tg of the resin, respectively. Flexural strength was evaluated and the results were analyzed by ANOVA/Tukey HSD test (α = 0,05). Result: Different nitrogen ratios were observed for groups 0, 5 and 10% (0, 0.85 and 5.82% respectively), there was copolymerization between the resin and PTBAEMA,and reduction of Tg after incorporation of PTBAEMA. Significant differences were found for flexural strength (p < 0.05), the mean values were 94.7 ± 9.4A, 21.8 ± 3.4B, 13.0 ± 1.5C MPa for groups 0,5 and 10%, respectively.Conclusion: The incorporation of PTBAEMA resulted in copolymerization, presence of amine groups on specimens? surfaces, and in decrease of Tg and flexural strength.


Subject(s)
Acrylic Resins , Dental Plaque , Denture, Complete , Denture, Partial , Flexural Strength , Anti-Infective Agents , Polymers , Analysis of Variance
14.
J. appl. oral sci ; 19(3): 195-199, May-June 2011. ilus, graf, tab
Article in English | LILACS | ID: lil-588122

ABSTRACT

Polymethyl methacrylate (PMMA) resins have commonly been used as a denture base material. However, denture bases may act as a reservoir for microorganisms and contribute to oral diseases in denture wearers. It is hypothesized that the 2-tert-butylaminoethyl methacrylate (TBAEMA) incorporated to acrylic resins should have antimicrobial activity related to the presence of amino groups on acrylic resin surface. OBJECTIVES: The objectives of this study were to evaluate the presence of amino groups on acrylic resin surface and the influence on flexural strength after incorporation of TBAEMA. MATERIAL AND METHODS: Six groups were divided according to the concentration of TBAEMA incorporated to acrylic resin (Lucitone 550): 0, 0.5, 1.0, 1.5, 1.75 and 2 percent. Specimens surface were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Flexural strength of the specimens was tested and results were analyzed by ANOVA and Tukey's test (α=0.05). RESULTS: Different nitrogen ratios were observed on specimen surfaces: 0, 0.13, 0.74, 0.66, 0.92 and 0.33 percent for groups 0, 0.5, 1.0, 1.5, 1.75, and 2 percent, respectively. Significant differences were found for flexural strength (p<0.001). The mean flexural strength values were 98.3±3.9, 93.3±3.2, 83.9±2.1, 82.8±5.2, 71.2±5.1 and 17.3±3.2 MPa for groups 0, 0.5, 1.0, 1.5, 1.75, and 2 percent, respectively. CONCLUSION: Within the limitations of this study, the incorporation of TBAEMA results in the presence of the potentially antimicrobial amino groups on specimen surfaces, but affect the flexural strength, depending on the concentration of TBAEMA.


Subject(s)
Acrylic Resins/chemistry , Denture Bases , Dental Materials/chemistry , Methacrylates/chemistry , Analysis of Variance , Anti-Infective Agents/chemistry , Materials Testing , Methylmethacrylate/chemistry , Surface Properties , Tensile Strength
15.
Rev. odontol. UNESP (Online) ; 40(3): 131-135, maio-jun. 2011. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-614433

ABSTRACT

Introdução: A incorporação de agentes antimicrobianos a resinas acrílicas pode ser uma alternativa para evitar a estomatite protética em usuários de próteses totais ou parciais removíveis. Entretanto, estes agentes podem afetar as propriedades mecânicas das resinas acrílicas para base protética. Objetivo: Esse estudo investigou o efeito da incorporação do polímero antimicrobiano 2-tert-butilaminoetil metacrilato (PTBAEMA) na resistência à flexão de uma resina acrílica. Material e método: Foram confeccionados espécimes de formato retangular a partir de uma resina acrílica para base protética (Lucitone 550) contendo 0% (controle), 1, 2,5, 5 e 10% de PTBAEMA. Os dados de resistência à flexão foram avaliados por meio de análise de variância a um fator seguida pelo teste de Tukey (a = 0,05). Resultado: Observou-se que a resistência à flexão diminuiu significantemente (p < 0,05) após a adição de PTBAEMA: 0% (91,3 ± 13,7A), 1% (71,4 ± 7,7B), 2,5% (9,4 ± 1,5C); 5% (7 ± 1,7C) e 10% (7 ± 1,2C). Conclusão: A resistência à flexão foi adversamente afetada após a incorporação do PTBAEMA. Futuros estudos são necessáriospara avaliar se a concentração de 1% permite uma possível aplicabilidade clínica para a resina acrílica estudada, visto que nesta concentração a resistência à flexão está dentro do limite estabelecido pela ISO (65 MPa).


Introduction: The incorporation of antimicrobial agents in acrylic resins can be an alternative to prevent denture stomatitis in partial or complete denture wearers. However, these agents can affect the mechanical properties of denture base acrylic resin. Objective: This study investigated the effect of incorporation of antimicrobial polymer 2-tert-butylaminoethyl methacrylate (PTBAEMA) on flexural strength of an acrylic resin. Material and method: Rectangular specimens were from a denture base acrylic resin (Lucitone 550) containing 0% (control), 1, 2.5, 5 and 10% of PTBAEMA. Data of flexural strength were evaluated by one way ANOVA, followed by Tukey test (a = 0.05). Result: It was observed that flexural strength significantly decreased (p < 0.05) after the addition of PTBAEMA: 0% (91.3 ± 13.7A), 1% (71.4 ± 7.7B), 2.5% (9.4 ± 1.5C); 5% (7 ± 1.7C) e 10% (7 ± 1.2C). Conclusion: Flexural strength was detrimentally affected after incorporation of PTBAEMA. Future studies arenecessary to evaluate if the 1% concentration allows clinical application for the acrylic resin studied, since flexural strength obtained was within ISO recommendations.


Subject(s)
Polymers , Stomatitis, Denture , Acrylic Resins , Denture Bases , Denture, Complete , Denture, Partial , Flexural Strength , Anti-Infective Agents
16.
Rev. odontol. UNESP (Online) ; 38(2): 85-91, mar.-abr. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-621800

ABSTRACT

O estudo da porosidade em resina acrílica para base protética tem sido realizado por meio de diversos métodos, entre os quais o método que associa a porosidade com a sorção de água pela resina acrílica, tendo como base o Princípio de Arquimedes. A determinação do momentoexato da pesagem do espécime para a avaliação da porosidade é necessária na aplicabilidade desta metodologia. O objetivo do presente estudo consiste em determinar o tempo mínimo necessário para que ocorra a estabilização da massa do espécime de resina acrílica durante os períodos de secagem e sorção de água, em função do tipo de resina (Acron MC e Clássico), da solução de armazenamento (soluções de cloreto de cálcio anidro a 25, 50, 75% e água destilada pura) edo formato do espécime (retangular e base protética maxilar). Os espécimes foram submetidos às etapas de secagem e sorção nas diferentes soluções e pesados a cada 24 horas. A partir domomento em que a estabilização das massas foi alcançada, um período três vezes maior foi aguardado, seguindo-se as pesagens, para confirmação desse período de estabilidade. Os dadosforam descritos por meio de curvas temporais de secagem e sorção de água dos espécimes. Os resultados sugerem que os períodos de secagem e sorção de água não sofreram influência do tipo de resina acrílica e da solução de armazenamento. Apenas o formato do espécime interferiu na determinação desses períodos: para o formato retangular, o período de secagem foi de 20 dias e o período de sorção de água, 30 dias; para a base protética maxilar, esses períodos foram de 30 e 40 dias, respectivamente.


Various methods have been used to study the porosity of denture base resin, among them the method that associates porosity with water sorption by the acrylic resin, based on the Archimedes Principle. When applying this method for evaluating porosity, it is necessary todetermine the exact moment of weighing the specimen. The aim of this study was to determine the minimum time necessary for stabilization of the acrylic resin mass of the specimen to occur, during the periods of drying and water sorption, as a function of the type of acrylic resin (Acron MC and Clássico), the storage solution (25, 50, 75% anhydrous calcium chloride solutions and pure distilled water) and specimen shape (rectangular and maxillary denture base). The specimens were submitted to the drying and sorption stages in the different solutions, and weighed every 24 hours. From the time when stabilization of the masses was reached, a three times longer period was waited, during which weighing continued, to confirm this period of stability. The data weredescribed by means of temporal drying and water sorption curves of the specimens. The results suggested that the period of drying and water sorption were not influenced by the type of acrylic resin and storage solution. Only the shape of specimens interfered in the determination of these periods. For the rectangular shape, the drying period was 20, and 30 days for water sorption. For the maxillary denture base these periods were 30 and 40 days respectively.


Subject(s)
Acrylic Resins , Porosity , Denture Bases , Denture, Complete
17.
Araraquara; s.n; jun. 2008. 154 p. tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-509986

ABSTRACT

O estudo da porosidade em resina acrílica para base de prótese tem sidorealizado por meio de diversos métodos, entre eles o método que associa a porosidade com a sorção de água pela resina acrílica tendo como base o Princípio de Arquimedes. O objetivo do presente estudo foi validar um método de análise da porosidade por meio de sorção de água em resinas acrílicas para base protética por meio da determinação de uma solução adequada de armazenamento dos espécimes (aw ótima), em função de dois formatos de espécime (retangular, de acordo com a norma ISO 1567 e formato de uma base protética) e duas resinas acrílicas para base protética processadas de maneiras distintas: banho de água (Clássico) emicroondas (Acron MC). As soluções de armazenamento utilizadas nesseestudo corresponderam a soluções de cloreto de cálcio anidro a 25%,50%, 75%, e água destilada pura. Após a determinação dos grupos onde se estabeleceu a aw ótima, foram calculados o fator de porosidade (FP) e o coeficiente de difusão (D) nesses grupos bem como para os grupos armazenados em água destilada pura. Os resultados de FP foram comparados por meio de análise de variância (ANOVA) para um fator, seguida pelo teste HSD de Tukey. Para o D, empregou-se o teste de Kruskal-Wallis, seguido do teste de Dunn (Acron MC, P=0,003; Clássico, P=0,020). Para todos os procedimentos estatísticos, o nível de significância foi _= 0,05. A partir dos resultados foi possível concluir que para a resina polimerizada em microondas (Acron MC), a aw ótima é uma solução de cloreto de cálcio anidro a 50% para o formato base protética e de 75% para o formato ISO. Já para a resina polimerizada em banho de água quente (Clássico), concluiu-se que os espécimes para avaliação daporosidade devem ser armazenados em solução de cloreto de cálcioanidro a 75% para o formato base protética e 50% no formato ISO. Concluiu-se também que, para uma mesma resina, o formato do espécime não...


Subject(s)
Acrylic Resins , Denture, Complete , Physical Phenomena , Porosity
18.
Araraquara; s.n; 2008. 186 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-590746

ABSTRACT

O estudo da porosidade em resina acrílica para base de prótese tem sido realizado por meio de diversos métodos, entre eles o método que associa a porosidade com a sorção de água pela resina acrílica tendo como base o Princípio de Arquimedes. O objetivo do presente estudo foi validar um método de análise da porosidade por meio de sorção de água em resinas acrílicas para base protética por meio da determinação de uma solução adequada de armazenamento dos espécimes (aw ótima), em função de dois formatos de espécime (retangular, de acordo com a norma ISO 1567 e formato de uma base protética) e duas resinas acrílicas para base protética processadas de maneiras distintas: banho de água (Clássico) e microondas (Acron MC). As soluções de armazenamento utilizadas nesse estudo corresponderam a soluções de cloreto de cálcio anidro a 25%, 50%, 75%, e água destilada pura. Após a determinação dos grupos onde se estabeleceu a aw ótima, foram calculados o fator de porosidade (FP) e o coeficiente de difusão (D) nesses grupos bem como para os grupos armazenados em água destilada pura. Os resultados de FP foram comparados por meio de análise de variância (ANOVA) para um fator, seguida pelo teste HSD de Tukey. Para o D, empregou-se o teste de Kruskal-Wallis, seguido do teste de Dunn (Acron MC, P=0,003; Clássico, P=0,020). Para todos os procedimentos estatísticos, o nível de significância foi _= 0,05. A partir dos resultados foi possível concluir que para a resina polimerizada em microondas (Acron MC), a aw ótima é uma solução de cloreto de cálcio anidro a 50% para o formato base protética e de 75% para o formato ISO. Já para a resina polimerizada em banho de água quente (Clássico), concluiu-se que os espécimes para avaliação da porosidade devem ser armazenados em solução de cloreto de cálcio anidro a 75% para o formato base protética e 50 % no formato ISO.


The study of porosity in acrylic resin has been carried out by means of diverse methods, among them the method that associates the porosity with the water sorption by acrylic resin which is based on Archimedes’ Principle. The aim of the present study was to validate a method of porosity analysis by means of water sorption in denture base resins by the determination of an adequate solution of specimens storage (optimal aw), as a function of two specimen shapes (rectangular in accordance with ISO 1567 and denture base shape) and two denture base resins processed in different ways: water bath (Clássico) and microwave-polymerized (Acron MC). The storage solutions used in this study were anhydrous calcium chloride solutions at 25%, 50%, 75%, and distilled water. After the determination of optimal aw, porosity factor (FP) and diffusion coefficient (D) have been calculated in these groups and for the groups stored in distilled water. FP results have been compared by one-way ANOVA, followed for Tukey HSD test. For D, Kruskal-Wallis test was performed, followed by Dunn test (Acron MC, P=0,003; Clássico, P=0,020). For all the statistical procedures, the level of significance was _= .05. From the results, it was possible to conclude that for Classico resin, the storage solution indicated for porosity evaluation is anhydrous calcium chloride solution at 50% for denture base shape, and 75 % for ISO shape. For the water bath-polymerized resin (Classico), it was concluded that the specimens for porosity evaluation must be stored in anhydrous calcium chloride solution at 75% for denture base shape and 50 % for ISO shape. It was also concluded that, for the same resin, specimen shape did not influence on FP since the specimens are stored in optimal aw established in this study.


Subject(s)
Acrylic Resins , Denture, Complete , Physical Phenomena , Porosity
19.
J. appl. oral sci ; 15(5): 424-428, Sept.-Oct. 2007. tab
Article in English | LILACS | ID: lil-465925

ABSTRACT

Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 sec, and manufacturing microwave cycle - 320W/3 min + 0W/3 min + 720W/3 min); T (Clássico, water bath cycle - 74ºC/9h) and Q (Jet, press chamber cycle - 50ºC/15 min at 2 bar). Ten specimens (65 x 10 x 3.3mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5 percent level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 ± 5.31; B = 107.57 ± 3.99; C = 109.63 ± 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 ± 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.

20.
Ciênc. odontol. bras ; 9(4): 76-83, out.-dez. 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-462887

ABSTRACT

A porosidade na resina acrílica (RA) é atribuída a uma série de fatores e pode interferir nas propriedades deste material e na estética das bases protéticas. Ela pode estar associada à polimerização incompleta da RA ou ao excesso de aquecimento durante a sua polimerização. A utilização da energia de microondas na polimerização da RA é um processo que apresenta como principal vantagem a economia de tempo nos procedimentos laboratoriais para a confecção de próteses totais. No entanto, é importante que se utilizem tempos e potências adequados para que não ocorra prejuízo às propriedades físicas e mecânicas da RA. O objetivo do presente trabalho foi verificar a presença de poros em diferentes regiões de bases protéticas de RA de prótese total superior, com espessura de 3,5 mm, processadas em três ciclos de polimerização por meio da energia de microondas: A) 500 W por 3’; B) 90 W por 13’ (mufl a na vertical) + 500 W por 90’’ (mufl a nahorizontal); C) 320 W por 3’ + 4’ 0W + 720 W por 3’. O grupo controle foi polimerizado em banho de água quente por 9 h a 74oC (ciclo T). Após o seu processamento, as bases foram seccionadas transversalmente em três regiões (anterior, média e posterior) e em cada região três áreas foram analisadas. As imagens dessas áreas foram capturadas em um microscópio e a área dos poros foi quantifi cada por um programa de computador (Leica). O teste de Kruskal-Wallis não detectou diferenças entre os diferentes ciclos e regiões das bases avaliadas (α=.05). Nenhuma diferença signifi cativa na porosidade foi encontrada em relação às regiões analisadas nas bases polimerizadas nos ciclos em microondas. Ainda, a quantidade de poros nas bases polimerizadas em microondas foi semelhante para as bases polimerizadas pelo método convencional, independente da região analisada. Concluiu-se que a presença de poros não sofreu infl uência do ciclo de polimerização e da área da base protética maxilar analisada.


Subject(s)
Acrylic Resins , Denture, Complete , Microwaves , Porosity , Image Processing, Computer-Assisted , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL